Journal of Manipulative and Physiological Therapeutics
Volume 23, Issue 1 , Pages 37-47, January 2000

Sitting biomechanics, Part II: Optimal car driver's seat and optimal driver's spinal model

Received 8 January 1999; received in revised form 26 January 1999

Abstract 

Background: Driving has been associated with signs and symptoms caused by vibrations. Sitting causes the pelvis to rotate backwards and the lumbar lordosis to reduce. Lumbar support and armrests reduce disc pressure and electromyographically recorded values. However, the ideal driver's seat and an optimal seated spinal model have not been described. Objective: To determine an optimal automobile seat and an ideal spinal model of a driver. Data Sources: Information was obtained from peer-reviewed scientific journals and texts, automotive engineering reports, and the National Library of Medicine. Conclusion: Driving predisposes vehicle operators to low-back pain and degeneration. The optimal seat would have an adjustable seat back incline of 100 from horizontal, a changeable depth of seat back to front edge of seat bottom, adjustable height, an adjustable seat bottom incline, firm (dense) foam in the seat bottom cushion, horizontally and vertically adjustable lumbar support, adjustable bilateral arm rests, adjustable head restraint with lordosis pad, seat shock absorbers to dampen frequencies in the 1 to 20 Hz range, and linear front-back travel of the seat enabling drivers of all sizes to reach the pedals. The lumbar support should be pulsating in depth to reduce static load. The seat back should be damped to reduce rebounding of the torso in rear-end impacts. The optimal driver's spinal model would be the average Harrison model in a 10 posterior inclining seat back angle. (J Manipulative Physiol Ther 2000;23:37–47)

Keywords:  Sitting, Biomechanics, Lordosis, Ergonomics, Spinal Model, Motor Vehicles, Whiplash Injury, Chiropractic

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 15.00 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

 Submit reprint requests to: Donald D. Harrison, PhD, DC, Chiropractic BioPhysics Nonprofit, Inc, 210 Bent Oak Circle, Harvest, AL 35749.

PII: S0161-4754(00)90112-X

doi:10.1016/S0161-4754(00)90112-X

Journal of Manipulative and Physiological Therapeutics
Volume 23, Issue 1 , Pages 37-47, January 2000