Journal of Manipulative and Physiological Therapeutics
Volume 29, Issue 2 , Pages 150-155, February 2006

Validity of Infrared Thermal Measurements of Segmental Paraspinal Skin Surface Temperature

  • Richard Roy, DC

      Affiliations

    • Module Chiropratique, Université du Québec à Trois-Rivières, Trois-Rivières, Quebec, Canada; and Département de Kinanthropologie, Université du Québec à Montréal, Montreal, Quebec, Canada
  • ,
  • Jean P. Boucher, PhD

      Affiliations

    • Département de Kinanthropologie, Université du Québec à Montréal, Montreal, Quebec, Canada
  • ,
  • Alain S. Comtois, PhD

      Affiliations

    • Département de Kinanthropologie, Université du Québec à Montréal, Montreal, Quebec, Canada
    • Corresponding Author InformationSubmit requests for reprints to: Alain S. Comtois, PhD, Département de Kinanthropologie, Université du Québec à Montréal, CP 8888, Succursale Centre-Ville, Montreal, Quebec, Canada H3C 3P8.

Received 11 April 2005; received in revised form 7 July 2005

Abstract 

Objective

The purpose of this study was to evaluate the validity of thermal measurements by infrared camera thermometry.

Methods

Seventeen subjects underwent a 30-minute acclimatizing period in a controlled environment room. Thermal recordings were executed at the levels of C4 and L4. Fifteen recordings per segment were acquired in an alternating mode that always started at L4. Each subject was required to participate on 5 occasions. The exclusion criteria for the subjects included the following: no inflammatory disease or fever, no consumption of beverages containing caffeine, and no participation in physical activity 2 hours before the recording session; female subjects could not be menstruating on a day of recording.

Results

A total of 2550 recordings for the cervical area and the lumbar area was recorded. Strong significant correlations were found for the left (r = .77) and right (r = .71) lumbar sections (P < .0001) whereas weaker significant correlations were observed for the left (r = .56) and right (r = .63) cervical areas (P < .0001). The limits of agreement (Bland-Altman) showed good relationships but poor interchangeability.

Conclusions

In this study, the infrared cameras showed that they were valid tools in a controlled environment; however, the technique for the cervical measurements needs to be reassessed.

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 15.00 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

 Sources of support: Funding provided by the Fondation Chiropratique du Québec.

PII: S0161-4754(05)00373-8

doi:10.1016/j.jmpt.2005.12.004

Journal of Manipulative and Physiological Therapeutics
Volume 29, Issue 2 , Pages 150-155, February 2006